M系列

 提示:點(diǎn)擊圖片可以放大

 



公司2005年最新推出全新HIMOD M系列,秉承系列模塊化機(jī)房專(zhuān)用空調(diào)的全部?jī)?yōu)點(diǎn)谓晌,高精度恒溫控制型彌漫式送風(fēng)。

M series is launched in 2005. It has all of the advantages of our series modular room air-conditioninghigh precision temperature control type, and diffuse type air flow.

 

    彌漫式送風(fēng)型號(hào)為S/MX XKA 

Diffuse air flow model – S/MX XKA

彌漫式送風(fēng)空氣在機(jī)房的循環(huán)方式

Diffuse type air circulation in the computer room

    冷空氣由空調(diào)下部送出癞揉,在地板平面流動(dòng)纸肉,依據(jù)流體力學(xué)原理,冷空氣分布在機(jī)柜的中部和下部喊熟,在機(jī)柜的周?chē)纬衫淇諝獾?span lang="EN-US">“包圍柏肪,空氣受熱上升,在房間內(nèi)依靠熱動(dòng)力流動(dòng)芥牌。計(jì)算機(jī)機(jī)柜在底部吸入冷空氣烦味,計(jì)算機(jī)或機(jī)柜本身的強(qiáng)制通風(fēng)設(shè)備完成空氣的循環(huán),受熱的空氣由機(jī)柜上部排出壁拉。

Cold air from air conditioning is out in the floor plane flow. Based on the principle of fluid mechanics, the cold air is distributed in the middle and lower cabinet. The cabinet is formed around the "siege" of cold air, and the hot air rises relying on the "thermal" flow in the room. Computer cabinet at the bottom is sucked the cold air, forced ventilation device of a computer or the cabinet itself complete air circulation, the heated air is discharged by the top of cabinet.


    彌漫式送風(fēng)空氣在機(jī)房?jī)?nèi)的循環(huán)方式 

    相對(duì)于下送風(fēng)方式谬俄,彌漫式送風(fēng)方式不需要架空地板,而單位面積的熱負(fù)荷可提高10%扇商,同時(shí)房間層高要求降低厨棒,普通房間都可作為機(jī)房使用棠吨。

    由于機(jī)柜被冷空氣包圍桑趴,相對(duì)于下送風(fēng)方式,彌漫式送風(fēng)方式下機(jī)柜的冷卻效果更佳逻盅。

    而對(duì)于上送風(fēng)方式盔连,彌漫式送風(fēng)方式不需要風(fēng)管,避免了房間的溫度的不均勻的情況的發(fā)生 阻羞,同時(shí)可以節(jié)能10%-20%凰染,降低空調(diào)制冷量需求10%

Diffuse type air circulation in the computer room

Relative to the lower air supply, the diffuse type does not require overhead floor, while the heat load per unit area can be increased by 10%, and reduces the requirement of storey rooms, common room can be room.

The cabinet is surrounded by the cold air relative to the lower air supply, and it provides better cooling effect for the diffuse type.

But for the upper air supply, the diffuse type ventilation does not need wind pipe to avoid the inhomogeneous temperature of the room, and also can save energy up to 10%-20% and reduce air conditioning demand of 10%.

 

  彌漫式送風(fēng)方式的優(yōu)勢(shì) 

    單位面積熱負(fù)荷提高10%忘拧,降低機(jī)房建筑層高要求捏诫,節(jié)省安裝費(fèi)用,節(jié)省運(yùn)行費(fèi)用多種冷卻方式溃擒,包括風(fēng)冷连定,水冷,乙二醇冷卻叮洋,乙二醇自然冷卻磁携,冷凍水,雙冷源等良风,配合用戶室外的綜合現(xiàn)場(chǎng)條件對(duì)冷卻的要求谊迄,儲(chǔ)液罐式冷凝器,可保證機(jī)組在環(huán)境溫度低至-34.4℃都可正常運(yùn)行烟央,運(yùn)用了大量環(huán)保節(jié)能技術(shù)统诺,包括采用無(wú)環(huán)境污染的原材料和機(jī)組防腐涂料歪脏,大量采用可重復(fù)使用的部件,增強(qiáng)機(jī)組的可維護(hù)性粮呢,先進(jìn)的微處理器具有順序優(yōu)先啟動(dòng)功能唾糯,使機(jī)組部件磨損平均,延長(zhǎng)機(jī)組使用壽命鬼贱,雙制冷系統(tǒng)運(yùn)行移怯,節(jié)能且更加可靠,高效低能耗的壓縮機(jī) 这难,采用模糊邏輯控制絕對(duì)溫度控制等先進(jìn)調(diào)控技術(shù)舟误,提高控制精度,降低能耗躲窜,延長(zhǎng)機(jī)組使用壽命 沃羽,先進(jìn)的故障自動(dòng)報(bào)警系統(tǒng)和開(kāi)機(jī)自診斷功能,使診斷處理機(jī)組的問(wèn)題更加快捷咧笔。

The advantage of diffuse type

The heat load per unit area was increased by 10%. The diffuse type reduces the height of building, saves the installation cost, and saves multiple cooling mode andoperating costs including air cooling, water cooling, ethylene glycol, ethylene glycol natural cooling, freezing water, double cold source. Cooperate with the general conditions of outside for the requirement of cooling, the liquid storage tank condenser can guarantee the normal operation of the unit achieving the low temperature to -34.4. The use of a large number of environmental protection and energy saving technologies includes the use of raw materials and the anticorrosive paint without environmental pollution, extensive use of reusable components, and enhanced unit maintainability. The advanced microprocessor has the priority of starting function, makes the unit parts wear on average, and prolongs the service life. Dual fluid refrigeration system increases the energy saving and is more reliable, high efficiency and low energy consumption. The compressor is used the "advanced control using fuzzy logic control" and "absolute temperature control" technology to improve the control precision, reducing energy consumption, prolonging the service life, automatic fault alarm system, and booting diagnosis function which makes the diagnostic problems more quickly.

應(yīng)用的范圍 Application

    * 電信交換機(jī)房  網(wǎng)管中心

* Communication room * Network center

    * 衛(wèi)星控制中心  * IDC數(shù)據(jù)中心

Satellite control center * IDC data center

    * 動(dòng)力機(jī)房    實(shí)驗(yàn)室

*Power room * Laboratory

    * 培訓(xùn)中心    標(biāo)準(zhǔn)室

*Training center * Standard room

 * 潔凈室     工業(yè)控制中心

* Clean room * Industry control center

精密加工中心  * UPS機(jī)房和電池室

* Precision machine center * UPS room and battery room

This chart is for reference only, the new design of components and structures for the unit will change depending on the actual situation.

此工程圖僅供參考鉴膝,新機(jī)型所使用的元件及機(jī)組內(nèi)部的設(shè)計(jì)會(huì)根據(jù)實(shí)際狀況而有所變動(dòng)。