針對(duì)通訊機(jī)房的空調(diào)解決方案沉享,通訊機(jī)房的特點(diǎn)為訊息傳遞工作場(chǎng)所,通訊機(jī)房有大量發(fā)熱設(shè)備暴彻,通訊機(jī)房?jī)?nèi)人員不會(huì)太多星自。根據(jù)通訊機(jī)房的特點(diǎn),空調(diào)選型推薦如下:I52機(jī)型芋沽。
This is a solution of A/C for a communication room. The characteristic of the communication room is the workplace in data transmission facility, and there is a large amount of equipment. Personnel are not too much. According to the characteristics of the space for the communication room, the selection of model is recommended as I52.
經(jīng)濟(jì)效益評(píng)估:(Economic Evaluation)
This is a solution of A/C for a communication room. The characteristic of the communication room is the workplace in data transmission facility, and there is a large amount of equipment. Personnel are not too much. According to the characteristics of the space for the communication room, the selection of model is recommended as I52.
經(jīng)濟(jì)效益評(píng)估:(Economic Evaluation)
- 該通訊機(jī)房需安裝空調(diào)面積總計(jì)100平方米左右,有大量發(fā)熱設(shè)備(10KW)七冲,對(duì)溫濕控制及節(jié)能有要求痛倚,依據(jù)實(shí)際情況每平米所需制冷量平均按400W計(jì)算,總需求50KW制冷量澜躺。
The total area is of about 100 square meters for the communication room, and there is a large amount of heat source (10KW), and it requires the temperature and humidity control and energy saving features. Required cooling capacity per square meter on average calculated based on the actual situation according to 400W, the total demand for cooling capacity is of 50KW.
- 要滿足該項(xiàng)目50KW的制冷量蝉稳,需使用I52機(jī)組1套裝機(jī)。
To meet the cooling capacity of 50KW, this project is needed to use one set of unit (I52).
- 經(jīng)濟(jì)效益對(duì)比估算:傳統(tǒng)空調(diào)滿足50KW制冷量的輸入功率至少為18KW左右掘鄙,而I52機(jī)組1套主機(jī)的輸入功率合計(jì)為12.15KW耘戚,主機(jī)部分省電32.5%,全年共計(jì)節(jié)省電費(fèi)1.1萬(wàn)元以上操漠。(按1年運(yùn)行8個(gè)月收津,1月運(yùn)行30天,1天運(yùn)行8小時(shí)浊伙,用電按1元1度計(jì)算)
Comparison of economic benefit estimation: the traditional air-conditioning input power (50KW cooling capacity) is at least about 18KW, and the I52 input power per set is of 12.15KW. The energy saving is up to 32.5%. The annual saving is more than 11000 CNY. (According to 8 months per year, 30 days per month, 8 hours per day of operation, electricity by 1 CNY/1 degree calculation)